Geomechanics Deep Water Cores Measurement
Rock Fluid Imaging Lab provides geomechanical Triaxial test- in ultra high pressure and PC based Lab for deep water /target

Servo-control Close-loop test system manufacture and key feature Programmable Pressure Scenario, Controllable pressure, available close-loop scenario, PC based control.
- Test frame loading capacity up to 200 Ton ~ 2. 10^6 Newton.
- Confining pressure range up to 60.000 Psi. Confining pressure rate 0.5 bar /minute (7.25 Psi/minutes)
- Axial stress up to 200.000 Psi
-
Pore pressure control system and pressure rating Controllable Pore pressure, range from zero to maximum 20.000 Psi.
-
For standard triaxial measurement, the pore system should be vented to atmospheric pressure.
-
Displacement /strain sensor type, resolution Two sensor axial, and two radial sensors.
-
Data sampling rate Sampling rate:
-
Core plug size : diameter 1 inch and 1.5 inch with minimum length twice its diameters.
Thick Walled Cylinder Test
|
Servo-control. Close-loop test system manufacture/ and key feature Programmable Pressure Scenario, Controllable pressure, available close-loop scenario, PC based control. Displacement /strain sensor type, resolution Two sensor axial, and two radial sensors
- Confining pressure range up to 10.000 Psi
- Axial stress Axial stress up to 48.000 Psi
- Sensor type : strain gauge displacement sensor setup
- Resolution : 0.1 micro meter
- Scale Scale for measure the accumulation of solid mass in the outlet.
- Resolution 0.1 mg to obtain fluid volume
- core plug size that could be tested core sample with inner diameter 1 inch and outer diameter 1.5 inch with minimum length twice its outer diameters.
- Fluid flow rate can be adjusted
- Data sampling Sampling rate: 1 data/ second (default, can be adjusted)
|

|
Seismic Rock Physics Core Measurement
We provide relationship among wave phenomena and reservoir’s parameter for various reservoir’s condition.
|
The output of this measurement and analysis are following:
- Vp and Vs under various Overburden pressure.
- Vp and Vs under various Pore pressure.
- Vp and Vs under various Fluid saturant (brine, oil and gas).
- Vp and Vs various Anisotrophic orientation.
- Vp and Vs various Fracture condition.
- Time dependent VpVs Measurement
|
 |
Liquid Permeameter for Acid Flow Test
Acid Liquid Flow Permeability measurement for simulating/analysis the Acidized (Carbonate) Reservoir.
 |
Differential pressure transducer There are 2 pressure gauge in inlet and outlet of core.
- Resolution: 1 psi
- Pressure Drive pressure: 9000 Psi
- Confining Pressure: 12000 psi
- Back Pressure: 4000 Psi
- Fluid Two type fluid source in inlet.
- Pressure rate between fluid are identic
Heating Elements Resolution: 1°C
- Max temperature : 400°F (204.4°C)
|
|
Scale Scale for measure the accumulation of fluid in the outlet
- Resolution 0.1 mg to obtain fluid volume
PC Based System PC Based System to control measurement, recording data and storing to the database and also displaying output data.
- Data sampling rate Standard: 1/second
- Optional : 0.1 second
Core sample Typically, the tests utilize 1” or 1.5" diameter core plugs that are 1"-3" in length.
Effluent samples at outlet In standard, effluent samples were analyzed for AI, Si, Ca, and Fe at geochemical laboratory.
Material Some part of flow system equipment’s was constructed of Hastelloy C-276 and Inconel C-276.
|
Helium Porosity Meter
- Sample Size :1.0 Inch and 1.5 Inch diameter core plug
- Gas Supply :Helium/ argon/ Air
- Core Holder : Hustler type of core samples of 1.0 inch and 1.5 inch diameter for grain volume/ pore volume
- Pressure Transducer range :0 -4000 psi
|
 |
Helium Permeability Meter
 |
- Sample Size 1.0 Inch and 1.5 Inch diameter core plug
- Gas Supply Helium/ argon/ Air
- Core Holder Hustler type of core samples of 1.0 inch and 1.5 inch diameter for grain volume/ pore volume
- Pressure Transducer range 0 -4000 psi
- Air Permeability Range 0-10000 mD
|
|
Porous Plate Capillary Pressure
- Pressure Range Up to 2000 psi
- Core Sample dimension Core Diameter: 1” or 1.5”
- Core length: 3”
- Sample Preparation Samples must be cleaned and dried at high temperature to remove any water in the pore system as water will act as a wetting phase in preference to air. (hot Soxhlet extraction and convection oven dry at 105 °C)
- Control and database storage PC based
|
|
Contact Angle
Thermal Conductivity Test
- Heating source for Hot Reservoir Resolution: 1°C
- Max temperature : 400°F (204.4 °C)
- Cooling source for cool Reservoir Resolution: 1°C
- Min temperature : -4 °C
- Known Metal Copper, density 8.94 g/cc
- Specific heat 390 J/Kg °C
- Temperature Sensor Total five sensor
- Resolution: 0.01°C
- Number of required sample Two core sample
- Data sampling rate Sampling rate:
- Default: 1 data/ second
- Optional: 1 data/0.1 second up to 1 data/0.01 second
|
 |
Thin Slice Imaging (Petrography)
 |
- Microscope magnification: 4x, 10x, 40x
- Microscope polarization : Cross Nicol polarization
- Image Sensor : 1/2" CMOS
- Pixel Size : 3.2μmX3.2μm
- Image Output : USB2.0, 480Mb/s
- Programmable Control : Image size, brightness, gain, exposure time
|
CT-Scan
- X-ray source : 40-85 kV, max 30mA.
- X-ray detector: 12-megapixel Camera
- Maximum object size:120 mm diameter, 1 m length, 20 kg
- Rotation Up to 0.1°per step
- Acquisition Data:Up to 4x faster scanning of objects with high aspect ratio
|
 |
Gas Chromatograph (GC Analysis)
Gas chromatography is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition.
 |
- Temperature range: -100oC to 400oC
- Temperature control:Proportional integration type,
- Temperature control accuracy: ± 0.1oC,
- Heating speed: Ambient to 350oC in 13 minutes,
- Cooling speed:350oC to 100oC in 3.5 minutes
- Two on-column injection ports, FPD, ECD models:One on-column injection port
- Stainless steel:6 m x 2,
- Stainless steel (FPD, ECD models):12 m x 1 Glass:5.4 m x 2,
- Glass (FPD, ECD models):5.4 m x 1,
- Capillary (with option):100 mx1,
- Capillary (ECD model, with option):100 m x 1
- Flow Control : carrier gas, Hydrogen, Air
|
TOC - Total Organic Content
TOC is the measure of the level of organic molecules or contaminants in purified water. TOC is an analytic technique that helps organizations understand whether the water they are using is pure enough for their processes.
- Multi-ramp/zones and multi-peaks
- 126 sample capacity
- No loss of light oil
- Precise Temperature
- Multi-point calibration
- True temperature for kinetics
|
 |
Laser Particle Size Analyzer (LPSA)
Laser diffraction particle size analyzers are used to measure the sizes of particles in a material. Particle size is calculated by measuring the angle of light scattered by the particles as they pass through a laser beam.